Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.
I moved my Scale server into the next room, laundry room, just so it’s out of sight. Replacing the drive is financially out of the question. I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load. Yeah, it’s not helping, thanks. Although it’s empty, so this is probably not the source of the constant HDD noise.
How to Convert a Recorded AnyDesk Session in 3 Easy Steps
For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
The timer values specified are in milliseconds, so this example will park the disk heads after 30 minutes of inactivity. If we wanted to allow the disk to still park its heads but at minimum frequency, setting the APM value to 7Fh (hdparm -B 127) seems to be the correct choice. Of the three disks that I decided need some attention, I have one Western Digital disk and two Seagate ones.
At somewhat larger scales, a number of drives can be connected directly to a SAS (or SATA) controller PCIe card. But, if the number of ports on the motherboard is sufficient to your needs, this is the easiest way to connect the drives to the system. We are going to focus on some of the most popular for SATA and SAS drives.
Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.
Connect to a computer or mobile device remotely, whether it’s across town or halfway around the world.
- I moved my Scale server into the next room, laundry room, just so it’s out of sight.
- Another important aspect of managing your storage system is configuring notifications.
- Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds.
- Once you’ve done so, you must test delivery to your “real” inbox—you don’t want to learn that delivery isn’t working after your storage has already become unavailable!
- While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
- Discover strategies to manage disk arrays on FreeBSD and related platforms/operating systems.
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than reveryplay one.
Recommended Recovery Tools
If you need more advanced functionality than mpsutil provides, LSI provides their native tools sas2ircu and sas3ircu for FreeBSD. On my system, this command produces a bright red LED lit for that slot, physically highlighting the correct drive to replace. So, to activate the LED for the first disk displayed above, we first need to determine the enclosure handle number (0001), and then the slot number of the disk (03). This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk. As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.
SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.
- It’s hard to imagine why your drives are that loud!
- The system is never idle really, it’s a server.
- For quietness, a noise reducing case, move it somewhere else, quieter drives, maybe SSD instead of hard drives, etc.
- At somewhat larger scales, a number of drives can be connected directly to a SAS (or SATA) controller PCIe card.
- NVMe on the other hand, supports multiple queues (often 64 queues, but the official specification allows for up to 65,536 queues) allowing for many commands to be run concurrently.
- However, I noticed that my HDD’s heads park (particulary Seagate Exos) every 3 minutes.
- It refreshes the disks SMART information every 5 min.
Stay Informed and Make Smart Business Decisions with Klara’s Resources
Once you’ve done so, you must test delivery to your “real” inbox—you don’t want to learn that delivery isn’t working after your storage has already become unavailable! If you’d feel safer with a team of experts monitoring your storage, consider a ZFS Support Subscription. If you rely on manually checking on your storage periodically, you will regret it. Another important aspect of managing your storage system is configuring notifications. Klara recommends embedding these details directly into the ZFS vdev properties of each disk—a feature Klara created, which will become generally available in the upcoming OpenZFS 2.2 release. In these configurations, your system may or may not support features like individual “locate” and “fault” LEDs.
Top downloads Remote control for Windows
My question is – is there a way to tell if a certain disk suffers from the issue prior to purchasing? For the system I’m monitoring here, the SSD that it boots from has a wearout indicator sitting on 95 of 100 (only 5% of the rated life consumed), visibly unchanged for a long time so it’s not very interesting as an example. (The properties like ID_SERIAL_SHORT can be queried on a running system using udevadm info, such as udevadm info /dev/sdd to get the properties of the disk currently assigned ID sdd.) Somewhat more useful for monitoring is the smartmon_load_cycle_count_raw_value, which provides the actual number of load cycles that have been done. Secondly what are your disk monitoring refresh intervals and what do you use on your system to monitor SMART disk health?
The parking rate basically drops to zero at the time I updated the settings for the Seagate drives, and the Western Digital one hasn’t changed because it needs to be powered off to change that setting and I haven’t done so yet. The other slight annoyance when setting the idle3 timer on WD drives is that changes only take effect when the drive is powered on, usually meaning the host computer must be fully shut down and started back up for any changes to be seen- this makes experimentation to determine how raw timer values are interpreted a slower and more tedious process. Of particular note, WD Green drives ship configured to park the heads after only 8 seconds of inactivity which could notionally wear out the disk in a matter of months if the heads are cycling more-or-less continuously! For drives made by Western Digital, the inactivity timer for parking the heads is called the idle3 timer.
Truenas SCALE Seagate Exos X16 Load Cycling, Heads Parking. Change of Idle_b and Idle_c values
Unnamed devices can be specified by their specific SES device and element number. This greatly reduces the chance of getting it wrong when you (or the datacenter technician) physically pulls the disk. You can also reboot, and GEOM will pick up the multipath when it first tastes the disks during boot.